Don't buy this junk!

A few things Chris Dougherty and I will be discussing next Thursday in our webcast

Everyone,

Just a reminder that Chris Dougherty (The RV-PHD) and I will be doing a live Webcast next Thursday, Oct 24 at 7:00pm Eastern Time discussing some of the things you SHOULD NOT buy for your RV. A few are a waste of money, but some are downright dangerous and could damage your RV or possibly kill you!

Join us next Thursday, Oct 24 at 7:00pm Eastern Time

Click on the picture above for the YouTube link and reminder or just click HERE

Here’s a few things we’ll be discussing

One of my readers sent in a link to a dangerous 50-amp Tesla adapter that plugs into a 3-prong welder outlet. And as he noted, there’s no ground connection between the male welder plug and the 50-amp RV side of the adapter. So plugging your 50-amp RV into this adapter will float the RV ground allowing it to develop a hot-skin voltage. Depending on the available leakage/fault current this could cause anything from feeling a tingle to electrocution when touching your RV!

7 thoughts on “Don't buy this junk!”

  1. When I had a previous camper it had a quality MSW inverter. The only thing I ever plugged into it that would not work was an electric mattress pad. It did not over heat , it just did not work.

  2. Where is the twist lock in that ? The product just looks like it plugs into a NEMA 10-50R (3 wire range) and converts it to a 14-50R (4 wire range/RV/Tesla). The 10-50R uses the same conductor for neutral and ground which was allowed (with certain conditions) for many years, (not like a 6-50R welder outlet which has no neutral) Mike, have you verified that the ground is actually floating or is it possible that the ground and neutral on the 14-50 side are tied together? If so, it would be not much different than wiring a 14-50R to your main service. Not saying the adapter is a good idea, but I am really curious if they really floated the ground as one reviewer claims.

    1. I’ve triple-checked, and the ground contact in the 14-50R (female) outlet is indeed isolated from all other contacts on both sides of the adapter. I’ll demonstrate this on-camera in our webcast next week. Pretty scary, isn’t it? 😱

      1. Yes, that is just plain stupid. BTW Mike, when I include technical info in my comments it is because I know a lot of DIYs and others are reading, it is not intended for you as I realize you already know the info and probably more.

        1. That’s the correct way to add a comment. This is really a teaching newsletter, so more basic information is always better.

  3. We have ruined two electric blankets using a MSW inverter. At that time, we didn’t know it was a problem. We have since switched to a pure syne wave inverter. No more issues!